Issue Type:
|
Bug
|
|
Affects Versions:
|
current |
|
Assignee:
|
Gregory Boissinot
|
|
Components:
|
envinject |
|
Created:
|
25/Jul/12 1:59 PM
|
|
Description:
|
On a node level there is PATH environment variable set:
D:\cygwin\bin;${VS71COMNTOOLS}..\IDE;${windir}\Microsoft.NET\Framework\v4.0.30319;${PATH}
Job has been set to set environments variable before SCM checkout with both 'Keep Jenkins Environment Variables' and 'Keep Jenkins Build Variables' checked.
In the build step I put 'echo %PATH%'. It shows that the original PATH is set (without D:\cygwin\bin;${VS71COMNTOOLS}..\IDE;${windir}\Microsoft.NET\Framework\v4.0.30319; part). At the same time in Injected Environment Variables tab I see that PATH was correctly enhanced with settings from node.
The issue did not happen before EnvInject installation and setup. Previously 'echo %PATH%' at build step showed correct path.
|
|
Environment:
|
Jenkins 1.472 on RHEL5 x86_64, Windows Server 2003 slave
|
|
Project:
|
Jenkins
|
|
Priority:
|
Major
|
|
Reporter:
|
Krzysztof Malinowski
|
|
|
|
This message is automatically generated by JIRA.
If you think it was sent incorrectly, please contact your JIRA administrators.
For more information on JIRA, see: http://www.atlassian.com/software/jira
|
|
OK, now I got similar error on a different project which does not even have EnvInject set. The project used standard 'set environment variables' setting to override PATH and it stopped working once EnvInject was installed. Original PATH setting has been used instead.